FLUKE 9500B DRIVER


The is able to deliver 6 GHz leveled sine wave and pulse edges of only 70 ps. With each B mainframe able to control up to five heads, all the signals required to calibrate a 4-channel oscilloscope with an external trigger can be supplied, controlled and switched without operator intervention or the need for external switching. In high performance instruments, this may introduce additional measurement uncertainties as cables and connectors are handled. A range of mainframes At Fluke Calibration, we recognise that we must address the highest levels of performance to maintain our undisputed leadership in the field of oscilloscope calibration. The introduction of the latest member of the Active Head family, , once again underlines our commitment to oscilloscope calibration. Register Log in Contact Us.

Uploader: Bradal
Date Added: 24 May 2016
File Size: 38.10 Mb
Operating Systems: Windows NT/2000/XP/2003/2003/7/8/10 MacOS 10/X
Downloads: 17338
Price: Free* [*Free Regsitration Required]

The world’s highest performance, fully automated, upgradeable oscilloscope calibration workstation Oscilloscope calibration can be complex, time consuming and expensive.

Active Heads are lightweight 5900b measuring only 14 x 6. Simultaneous output on 5 channels means no more lead changing and no more complicated signal multiplexers or impedance matching networks. Fast return-to-ground edges with amplitudes between 4. Active Head with 25 ps pulse capability. With each B 9500g able to control up to five heads, all the signals required to calibrate a 4-channel oscilloscope with an external trigger can be supplied, controlled and switched without operator intervention or the need for external switching.

The square and pulse markers can also be used to calibrate timebase jitter. What was considered to be fkuke cutting edge instrument only a few years ago may now be relegated to the general purpose pool. The introduction of the latest member of the Active Head family,once again underlines our commitment to oscilloscope calibration.

  DCL LCD MONITOR DRIVER

It means that the benefits of hands-free, fully-automated, accurate oscilloscope calibration are readily available to everyone at a price and performance level that your needs and budget can support, 95000b ensuring that, through performance upgrades, future needs will be met when the time demands it.

B Oscilloscope Calibrator

Vertical deflection gain DC levels and 10 Hz to kHz squarewaves are adjustable up to V with 5-digit amplitude resolution at 0. If you already need to work with higher performance instruments, you can jump right in at flkke point.

However, in practice, these partial solutions present their own problems. Over recent years, oscilloscope technology and performance levels have changed dramatically, a trend set to continue. They also calibrate Z-axis and horizontal deflection bandwidth. Performed manually, this work requires skilled operators to spend a substantial amount of flukr performing what are essentially repetitive tasks. A choice of four styles, plus the ability to highlight every tenth marker by increasing its amplitude, provides optimum visibility on analog and digital storage oscilloscopes.

Complete Functionality Vertical and horizontal deflection fluie Fast return-to-ground edges with amplitudes between 4.

9500B Oscilloscope Calibrator

Worse still, switching systems or multiplexers used to enable a degree of automation often contribute more errors and aberrations than the instrument being calibrated. Whatever amplitude you choose, controlled waveshape filtering ensures that all high-speed edges have an accurately defined energy distribution.

Over the last decade, the 95000b of choice has migrated from a two-channel instrument to a more complex four-channel device. The result is higher workload throughput, better calibration consistency, minimization of human error, and less requirement for operator training – in short, higher quality calibration at lower cost.

The hybrid within the head can route even a high frequency, externally generated calibration signal to the Active Head output.

  KU 0225 DRIVER

In a conventional, cabled environment, mismatches, unknown or unpredictable 95000b transmission properties and less than perfect connections all contribute to degradation of the signal between the calibrator output and the oscilloscope input. Therefore, any of the models listed above can be upgraded to higher performance at any time, an option which also applies if you already own one of our existing Series calibrators.

Fluke B used or new for sale at used-line

Today you can invest in a oscilloscope cal solution with performance at a modest MHz. With our fluuke focus on securing your investment, the Active Head is the latest product to fulfill this promise, allowing current users of the to upgrade their equipment to any B status and take advantage of more recent product and performance enhancements. When calibrating these instruments, it is necessary to move the calibrating signal from channel to channel as the procedure progresses.

As your workload changes, and higher performance fluie become more important, you can upgrade performance to 1. Even automated systems require significant manual intervention to complete elements of the most simple calibration procedures.

Leveled sinewaves to 6. Electrical Calibration Workload Matrix The challenge for those chartered with maintaining a calibration facility to support these instruments is how to keep up with this rapid progress.

The is able to deliver 6.

High level edges up to V pk-pk check the dynamic performance of input attenuators.